#1 Sensors should send their battery voltage alongside measurement results

开启中
mathias4 年前创建 · 0 条评论
mathias 评论于 4 年前

Sensors should send their battery voltage alongside measurement results. Required changes:

  • A new measurement type needs to be added to the protocol (battery state in percent?).
  • The sensors need to be modified to measure the battery state. The ATTiny ADC can be configured to measure the bandgap voltage (1.1V) relative to VCC, so the inverse is proportional to the battery voltage.
Sensors should send their battery voltage alongside measurement results. Required changes: - [ ] A new measurement type needs to be added to the protocol (battery state in percent?). - [ ] The sensors need to be modified to measure the battery state. The ATTiny ADC can be configured to measure the bandgap voltage (1.1V) relative to VCC, so the inverse is proportional to the battery voltage.
bernd4 年前mathias 指派
登陆 并参与到对话中。
未选择标签
未选择里程碑
未指派成员
1 名参与者
到期时间

未设置到期时间。

依赖工单

此工单当前没有任何依赖。

正在加载...
取消
保存
这个人很懒,什么都没留下。